Section Three | Troubleshooting
Elliptical | Bike Troubleshooting
>> Console Continued
Symptom Possible Cause Test Procedure Repair
Console Resets
Intermittently.
Poor connection
between power supply
and power jack.
-Verify that the power
supply is securely
inserted into the power
jack.
Failed power supply. -Perform voltage check
on power supply.
Replace power supply.
Failed console cable. - Verify console cable is
not pinched or
damaged.
-Perform voltage check
on console cable.
Reference p42.
Replace console cable.
Failed console. Replace console.
Only Time Works on
Console (No workload,
distance or calories.)
Failed sensor wire. -Perform RPM
continuity check.
Replace sensor wire.
Missing rpm magnet on
crank assembly or
misaligned RPM sensor.
-Visually verify presence
of magnet in pedal axel
and alignment of RPM
sensor.
Replace magnet and/or
reposition RPM sensor.
Failed console. Replace console.