Owner`s manual

66 | 2008 AFG Service Seminar [rev 1.3]
Section Three | Troubleshooting
Elliptical | Bike Troubleshooting
>> Resistance
Symptom Possible Cause Test Procedure Repair
No resistance change
or erratic or continuous
resistance change.
Tension cable is not
connected to the brake
or has failed.
-Verify that the tension
cable is connected to
the break or has not
failed.
Reattach cable.
Failed or improper
power supply.
-Perform voltage check
on adapter.
-Verify the adapter is
the correct voltage.
Replace power supply.
Failed console cable. - Verify console cable is
not pinched or damaged
-Perform voltage check
on console cable.
Reference p42.
Replace console cable.
Failed servomotor. -Perform voltage check
on servomotor.
Reference p40 and p41.
Replace servomotor.
Failed console. Replace console.
Resistance is Too Hard
or Too Weak.
Tension cable is not
connected to the brake
or has failed.
-Verify that the tension
cable is connected to
the break or has not
failed.
Reattach cable.
Magnetic brake is
positioned improperly.
-Verify the correct
position of magnetic
brake.
Reference p31.
Reposition the
magnetic brake.