May 2009 AfiFree Terminal 155i Installation Manual 111
Display Fields under Standalone Configuration
1. Milk Yield field
2. Animal ID field
Mode
Description
Example
Cleaning
Removal
Milking
OFF
3. Last Highest Conductivity
Mode
Description
Example
Cleaning
OFF if no fluid in a milk meter
The Current Conductivity of the cleaning fluid in AfiFree
conductivity units (updated every 3 sec end calculated by
average conductivity of last 3 sec)
Removal
OFF (before first milking or after reset)
The Maximum Conductivity of the milk at last milking in
AfiFree conductivity units
Mode
Milk Yield field display
Example
Cleaning
The Temperature inside of Milk Meter
Body
Celsius
Fahrenheit
Removal
Hyphen (before first milking or after reset)
Final milk yield (at end of previous milking before reset)
Milking
On-Line Milk Yield updated every 100 mSec