Installation manual

116 Appendix A User Information and Instructions P/N 9040322
Terminal 155i Alarms
Alarm and Malfunction Indicators
Terminal 155i indicates an alarm or malfunction by flashing or continuously lit LEDs
(green and red).
When Terminal 155i’s LEDs indicate an alarm, its display shows information about
the alarm. Table 28 shows how to identify which alarm Terminal 155i is indicating.
Alarm name
Alarm description
Activation
timing
Display
Red Lights
blinking
Red lights
continuous
High level
Health code
The animal has a code defined in
AfiSheep/ AfiGoat as a "High level
health code ".
Special start required
External start is blocked
Before the
milking
"Animal ID" field and
"Health code" field are
blinking
YES
NO
Medium level
Health code
The animal has a code defined in
AfiSheep/ AfiGoat as a "Medium
level health code ".
Special start required
Before the
milking
"Animal ID" field and
"Health code" field are
blinking
YES
NO
Low level
Health code
The animal has a code defined in
AfiSheep/ AfiGoat as a "Low level
health code".
Before the
milking
"Animal ID" field and
"Health code" field are
blinking
YES
NO
High
conductivity
The milk has conductivity high
than alarm conductivity level
defined by AfiSheep/ AfiGoat
During the
milking
"Animal ID" field and "actual
conductivity" field are
blinking
YES
NO
Low Milk Yield
Removing conditions are fulfilled,
but the milk yield is low than
minimum level predicted by
AfiSheep/ AfiGoat
After
removing
"Animal ID" field and
"predicted milk yield" field
are blinking
YES
NO
Sick animal
High conductivity alarm and
Low Milk Yield alarm
simultaneously
After
removing
"actual conductivity" field
and "predicted milk yield"
field are blinking
YES
NO
Dirty body
Three sequential animals have
milk conductivity less than "6"
AfiFree units
During the
milking
"Stall number" field &
"actual conductivity" field
are blinking
NO
YES
Pulsation
output fault
Pulsation output failed
Coincident
al
"Stall number" field and
"Pulsation" field are
blinking with
NO
YES
Vacuum
Shutoff output
fault
Vacuum Shutoff output failed
Coincident
al
"Stall number" field is
blinking and "Animal ID"
field blinks with
NO
YES