Appendix B Milking System Cleaning
Guidelines
This appendix provides guidelines and recommendations for cleaning the milking
systems. It contains the following sections:
Cleaning Recommendations (below)
Performing an Acid Wash (page 120)
WARNING
Always comply strictly with the instructions of the chemical manufacturers.
Failure to comply with instructions can cause injury and damage to
equipment.
Use gloves and protective goggles when working with chemical detergents.
Avoid mixing active detergents and acids in the same container.
CAUTION
Butyl Glycol or Butyl Cellusolve detergent in excess of 10% concentration
may damage plastic components of the system. SAE Afikim recommends
cleaning fluids with a maximum concentration of 10% Butyl Glycol or Butyl
Cellusolve.
Follow all of the manufacturers’ recommendations, including:
concentrations, temperatures, and cleaning-cycle times. Excessive use of
chemicals may damage the AfiFree155 body.
Leaving detergent inside the AfiFree155 body may damage its
components.
Avoid contact of pesticide materials with the exterior of the AfiFree155
body and Terminal 155i.
Clean the AfiFree155 body and Terminal 155i’s exterior with a moist cloth,
without detergent.
Cleaning Recommendations
Cleaning recommendations has the following parts:
Chemical Dispensing Pumps (page 119)
Vacuum Pump (page 119)
Liquid Volume (page 119)
Temperature and Cycle (page 119)
Cleaning Exterior Surfaces (page 120)
NOTE
To prevent deterioration in accuracy due to limestone residue on the
electrodes of the AfiFree155 body, perform three acid wash cycles every
week.