Installation manual

28 Chapter 2 Site Preparation Requirements P/N 9040322
Terminal 155i Positioning
Terminal 155i is mounted on a bracket, which can be fixed to a suitable wall or pipe.
Position Terminal 155i according to the following guidelines:
Where it is convenient for the milker to use the buttons and see the display
With minimum exposure to animals and water
Consistently throughout the parlor, so that each Terminal 155i is clearly
associated with its AfiFree Body.
Connection Box Positioning
Each AfiFree Body connects to other components through an AfiFree Connection Box
or a Plug-in Connection Box (PICB). During normal operation, there is no need for
access to the connection box. It can be placed high above the parlor floor, for
example on the overhead cable trough (wire duct).
Position the connection box according to the following guidelines:
High above the milking point to protect it from mechanical damage, excessive
dirt, and water
Located directly above the associated AfiFree155i milk meter
Out of reach of livestock
With at least 20 cm (8‖) clearance above the AfiFree Connection Box for the lid
to open
With the AfiFree Connection Box cover facing up for ease of opening