Installation manual

May 2009 AfiFree Terminal 155i Installation Manual 37
Mounting the
AfiFree Body
The AfiFree Body has a groove on each side (Figure 4, page 14) that fits the bracket
arms.
1. Make sure that the bracket locks are open on both sides of the bracket arms
(Figure 16).
Lock Yellow Pointer
(narrow side at front)
Arm
LockArm
Yellow Pointer
(narrow side at back)
Open
Closed
Figure 16: Bracket Lock
2. Slide the AfiFree Body into position by guiding the grooves on its sides (Figure
4, page 14) along the bracket arms; do not force the AfiFree Body into place.
3. Rotate both bracket locks 180° (Figure 16) to lock the unit into place.
4. Connect the milk outlet to the milk line and check the following:
Make sure that all connections are tight.
Make sure that the line connecting the AfiFree Body to the milk line
maintains a 1.5
o
downslope.
Wiring the
AfiFree Body
WARNING
Take appropriate precautions to prevent injury from electric shock.
Wrap and seal a supplied adhesive-warning label (P/N 9040455)
around the AfiFree body connection cable
The AfiFree Body is supplied with a short pigtail cable terminated in a plug (Figure 4,
page 14). Connect this as follows:
Installations using AfiFree Connection Boxessee Wiring to an AfiFree
Connection Box (below)
Installations using (PICB)see Connecting to a Plug-in Connection Box (below)