Installation manual

May 2009 AfiFree Terminal 155i Installation Manual 49
Install the shut-off valve and holder as follows:
When the AfiFree Body has its milk inlet on the leftsee Figure 25
When the AfiFree Body has its milk inlet on the rightsee Figure 26
1. Attach the Generic Shut-off Valve Holder to the generic shut-off valve bracket
using the two hexagon socket screws.
2. Remove the shut-off valve from its packaging.
CAUTION
A vacuum NO operated valve must have washers between it and its
holder, as in Figure 25 and Figure 26. This stops the valve pressing
against its holder.
Attach the shut off valve to the Generic Shut-off Valve Holder using the two
hexagon head bolts, washers, spring lock washers, and nuts.
3. Connect the milk pipe between the shut-off valve’s outlet and the AfiFree Body’s
inlet.
4. Connect the shut-off valve’s inlet to the long milk tube.
Bolt
Vacuum NO Operated
Shut-off Valve
Generic Shut-off
Valve Bracket
Generic Shut-off
Valve Holder
Hexagon Socket
ScrewWasher
Washer
M6 DIN 9021
Air/Vacuum NC Operated
Shut-off Valve
Washer
Spring Lock
Washer
Nut
Holes for Hexagon
socket screw
Press Nuts for
Hexagon socket screw
Figure 25: Mounting Shut-off Valve for AfiFree BodyMilk Inlet on Left