Installation manual

72 Chapter 4 System Configuration P/N 9040322
Table 18: Wash Time Intervals
Measurement
Parameter
DIP
Switch
From the beginning of Cleaning Mode until the farthest*
AfiFree Body is filled with liquid
Time On
DSW1
From the end of Cleaning Mode until the nearest* AfiFree
Body is empty
Time Off
DSW2
*NOTE
―Farthest‖ and ―Nearest‖ refer to distance from the Parlor Wash System.
2. Set DIP switches DSW1 and DSW2 according to the time intervals measured in
step 1. Figure 38 shows DIP switch positions for different time intervals.
NOTE
To double parameter values for DSW1 and DSW2, move the DSW4
switch 3 to OFF.
For example, if switch 3 on DSW4 is set to OFF then 1 second becomes 2
seconds, 2 seconds becomes 4 seconds, etc.
Figure 38: DSW1 and DSW2DIP Switch Options for
NOTE
The above figure is also displayed on the label on the inside of the Wash
Controller lid.
Setting the Wash Duration Parameter
The Wash Duration parameter is required only for Manual Mode.
Set the Wash Duration parameter in accordance with the local parlor operation
doctrine. General guidelines are given in Appendix B. In most cases, a 2030 minute
wash cycle is suitable.
Set the Wash Duration parameter using DIP switch DSW3. Figure 39 shows DIP
switch positions for different wash durations.