Installation manual

May 2009 AfiFree Terminal 155i Installation Manual 75
Paramet
er
Paramete
r
Parameter
description
Key
combi
nation
Display view
example
Min.
Value
Max.
Value
Step
Units
Default
value
F3
Removal
Delay
Delay between
Vacuum closing and
Removal
"F"+"3"
1
9
1
sec
1
G
Measureme
nt coefficient
Measurement
coefficient
"F"+"4"
85
115
1
%
100
ODD
Milk
Remainder
Oddments milk
constant addition
"F"+"5"
0
300
10
gram
50
RAL
Removal
Alarm
Duration of green
lights blinking before
Removal
"F"+"6"
0
30
1
sec
0 (OFF)
SH
Sweep
Delay
Delay between
Removal and Sweep
start
"F"+"7"
0
9
1
sec
1
SL
Sweep
Pulse
Duration
Sweep Pulse
Duration
"F"+"8"
500
5000
500
mSec
500
NBS
Sweep
Pulses
Number
Number of Sweep
Pulses
"F"+"9"
0
5
1
3
IOC
IO
Configuratio
n
Pulsation control or
Back Flush control
Stall #
+"1"
0
3
1
0
Cu
Flow Control
Pulsation
Curves of milk flow
controlled pulsation
Stall #
+"2"
0
8
1
0 (OFF)
PF
Pulsation
Frequency
Constant Pulsation
Frequency set
Stall #
+"3"
30
180
1
p/min
120
PR
Pulsation
Ratio
Constant Pulsation
Ratio set
Stall #
+"4"
50
80
1
50
PTP
Reverse
pulsation
Reverse Pulsation
Ratio
Stall #
+"5"
0
1
1
0 (OFF)
STR
Strip
Flow for Strip
activating
Stall #
+"6"
0
2000
10
g/min
0 (OFF)
BFD
Back Flush
Delay
Delay between
Sweep end and
Back Flush start
Stall #
+"7"
1
9
1
Sec
2
U1
Water Back
Flush
Water Back Flush
Duration
Stall #
+"8"
0
9
1
Sec
0 (OFF)
A1
Air Back
Flush
Residue Air Back
Flush Duration
Stall #
+"9"
0
9
1
Sec
0 (OFF)
Kg/Lb
Weight Units
Weight Units
Animal
ID +"1"
Kg
C/F
Temperature
Units
Temperature Units
Animal
ID +"2"
C
STD
Stimulation
Duration
Stimulation Duration
Animal
ID +"3"
0
55
5
Sec
0 (OFF)
STF
Stimulation
Frequency
Stimulation
Frequency
Animal
ID +"4"
90
300
10
p/min
300
SR
Stimulation
Ratio
Stimulation Ratio
Animal
ID +"5"
50
80
1
50
CT
Maximum
AMT
Maximum Milking
Time
Animal
ID +"6"
0
1200
10
Sec
0 (OFF)
CC
Low Cluster
in Removal
Delay to Cluster
lowering in Removal
Animal
ID +"7"
0
25
1
Sec
0 (OFF)