May 2009 AfiFree Terminal 155i Installation Manual 91
Automatic address definition
Automatic Load Software
Automatic Load Tables
A parameter is enabled when its value is 1.
7. To accept the settings, press OK.
Removing a Malfunctioning Terminal 155i
1. Unplug the Terminal 155i cable from the Terminal 155i.
2. Push the Terminal 155i up, until the top clip is above the bracket.
3. Using two hands, pull the Terminal 155i towards you, freeing it from the bracket.
Installing a Replacement Terminal 155i
1. Mount the replacement Terminal 155i on the Terminal 155i bracket, as described
in Mounting the Terminal 155i (page 41).
2. Plug the Terminal 155i cable into the replacement Terminal 155i.
Checking and Preventive Maintenance
The checks listed below should be made from time to time, and especially before the
national cattle breeders association performs the annual weighing procedure. The
checks are divided into pre-milking checks (below) and post-milking checks
(page 92).
Pre-Milking Checks
1. Terminal 155icheck for faults.
2. AfiFree155i bodiesdo the following:
Check for defects
Check proper assembly to the parlor frame.
Re-tighten all fasteners.
Check that AfiFree155i bodies are properly leveled.
Make sure there is no fat or milkstone residue inside bodies.
Make sure there are no foreign particles inside bodies.
3. Air bleeder on the AfiFree155i bodies’ coversmake sure there is no blockage.
4. Washing valve diaphragm (on AfiFree155 body)do the following:
Check for defects and replace as necessary