Operation Manual

35
TROUBLESHOOTING AND FAULT REPAIR (Cont.)
No.
Symptom
Probable Causes
Remedy
7
Breeze S does not
move when
squeezing the
Operating Lever .
ü Main Key Switch
is in OFF position.
ü
Charging Plug
is installed in
Charging Socket.
ü
The Mechanical
Release Lever
of the
electromagnetic
Brake is operated .
ü Other inhibit :
Panic brake.
ü
Control system
failure.
ü Turn the key to
“ON” position.
ü Disconnect the
Charging Plug from the
Breeze S
.
ü Remove lever to
engaged position .
ü Reset by switch
OFF and ON again.
ü Call for technical
support.
8
Intermittent drive.
ü Battery capacity
low.
ü Failed
connections
ü Faulty battery.
ü Charge batteries for
at least 18 hours.
ü
Remove Batteries
Cover and check the
battery cables
connection. In case of
corrosion of the
terminals, clean
the
terminals with a damp
clean cloth.
ü
If, after recharge,
the red leds are still ON,
the battery may be
faulty. For replacement,
contact your dealer.
9
Main or rear lights or
Blinkers
light are
inoperative.
ü Faulty LED light
board or Electronics
fault.
ü Call technician for
assistance.
10
When driving uphill or
carrying heavy loads
the
Breeze S
speed is
decreased gradually
but still moving.
ü The
Breeze S
controller
exceeded too high
temperature.
ü It is recommended
to stop the
Breeze S
and let the controller
cool for awhile.