5.3 Mounting Process
Every AfiPass II Controller is provided with two support plates on the back, see Figure 5 below. The
box can hang from the support plates. Alternatively, the support plates can be attached to the box
“upside-down”, and the plates can support the box above the point of attachment to the wall or
beam. The latter method is useful in mounting the box on a beam with little overhead clearance, as
the Box's cover opens upwards. The support plates protrude 6.5 cm (2
5
/
8
”) from the edge of the box.
An M6 bolt, washer, and two nuts are used to secure the support plates to the wall or beam.
To mount the AfiPass II Controller:
1. Attach the support plates to the box as shown in see below.
Caution: Mount the AfiPass II Controller on a stable, non-vibrating structure.
Figure 5 - AfiPass II Mounting Equipment
2. Bolt the AfiPass II Controller firmly to the wall or beam.