AfiPass II Control PCB Layout
The control PCB is the main board of the device which contains all functional components and
connectors.
The following figure shows the connectors and DIP switches on the AfiPass II Controller's Control
PCB:
Figure 7 - AfiPass II Controller PC Board Layout
AfiPass II Control PCB Connections
The connectors are numbered and have a prefix J.
Table 10 – Connections to the AfiPass II Controller
Connector Cable
Connects to
Wires for Afimilk source cables
Device
Connection
J1
Signal
(3-wire)
PC Comm. In
PC RS485
communication
1 GND (Blue)
2
B (White)
3
A (Yellow)
J2
Signal
(3-wire)
PC Comm. Out
PC RS485
communication
1
GND (Blue)
2
B (White)
3
A (Yellow)
J3
N/A
Future application
J4
Input
(2x2-wire)
Ex.I & En.I
Entry and exit gates
from side I
1
Either entry I gate wire
2
Either entry I gate wire
3
Either exit I gate wire
4
Either exit I gate wire