Instructions / Assembly

HD Supply Wall Sconce
Fluorescent Wall Fixture
Model: 324292 120VAC / 60Hz
8060667 R5
1 of 1
Limited Factory Warranty
AFX warrants this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions for a period
of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components; it
does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.
Safety Precautions
Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with these
instructions could result in potentially fatal electric shock and/or
property damage.
It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.
Do not handle any energized fixture or attempt to energize any fixture
with wet hands or while standing on a wet or damp surface or in water.
This fixture is designed for use in a 110-120VAC, 60Hz fused circuit.
Do not use on a dimming circuit.
To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) contact
between this fixture and the ground connection of your main power
supply panel.
This fixture is intended to be used for general indoor lighting in dry
locations.
ASSEMBLY INSTRUCTIONS
1. Preparing for installation
A. Disconnect electrical power at fuse or circuit breaker box before installing or servicing any part of this fixture.
B. Carefully remove the fixture from the carton.
2. Wiring – all wiring must take place inside junction box (not included)
Caution: Make sure power is off at fuse or circuit breaker box. Check power wires for damage or scrapes. If
power supply wires are within three inches of the ballast power supply, use wire suitable for at least 90C (194F).
Note: Most dwellings built before 1985 have supply wire rated to 60C. Consult a
qualified electrician before installing.
A. Install gem bar (1) (supplied) on the junction box (not supplied) by securing it
with two (2) screws (2) (supplied).
B. Insert threaded stem (3) into the gem bar (1). Leave about ½” stem length
exposed. Secure the stem with the nut (4) (supplied).
C. Pre-install the fixture on the wall by inserting the fixture backpanel (6) through
the stem (3). Mark four fixture mounting holes location by using backpanel as a
template (dimensions between holes 4 3/8” x 7 5/8”).
D. Remove the fixture and drill four holes for the anchors (5) (supplied). Install
four anchors (5) into the wall.
E. Pull the supply wires and the ground wire out from the outlet box (not
supplied).
F. Make all wire connections to appropriate wire. Secure with wire nuts (included).
G. Connect the green wire from the fixture to the power source green wire.
H. The black wire from the fixture is connected to the black wire from power
source.
I. The white wire from the fixture is connected to the white (neutral) wire from
power source.
J. Tuck all connections neatly into junction box.
3. Mounting
A. Place the fixture on the wall by inserting backpanel (6) through the stem (3).
B. Align the backpanel mounting holes with the installed acorns.
C. Install the fixture by securing it with four (7) screws (supplied) and one decorative nut (8).
4. Installing Lamps – Insert lamps (9) into lamp sockets (10) and press upward (or downward) until lamp snaps in
place.
5. Lens – Slide lens (11) into the frame.
6. Restore power at fuse or circuit breaker box.

Summary of content (1 pages)