Installation Sheet

LED Indoor Luminaires
Ceiling Mount
120VAC / 60Hz
Page 1 of 2 8061109 R1
Model #: ASHF121400L30D1xx
Model #: ASHF162600L30D1xx
Limited Factory Warranty
AFX Inc. hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions for a
period of 5 years from date of shipment from factory. This warranty covers all component parts and extends only to replacement of defective fixture or
components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.
ASHF1626L30D1
model shown
Safety Precautions
Read all safety precautions and installation instructions carefully before installing or servicing this fixture. Failure to comply with these instructions could result
in potentially fatal electric shock and/or property damage.
It is recommended that a qualified electrician perform all wiring. This fixture must be wired in accordance with all national and local electrical codes.
Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water.
This fixture is designed for use in a 120VAC, 60Hz fused circuit only. This fixture is compatible with a TRIAC (forward-phase or leading-edge) / ELV (reverse-
phase or trailing-edge).
To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding, there must
be a separate ground wire (green) contact between this fixture and the ground connection of your main power supply panel.
This fixture is intended to be used for general indoor lighting in dry or damp locations.
Disclaimer
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Canadian ICES-
005 (B) / NMB-005 (B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiver antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult with the dealer or an experienced radio/TV technician for help.
Any modifications to this fixture may void the warranty and interfere with the safe operation of the luminaire.
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device
Assembly Instructions
Step 1 Preparing for installation
A. Disconnect electrical power at fuse or circuit breaker box before installing or servicing any
part of this fixture.
B. Carefully remove the fixture from the carton, remove components from hardware kit.
C. Install mounting bracket (2) to the junction box (not included) using two screws to (3) secure it.
D. Install two wood screws (6 not provided) through the outer slots of bracket (2) into drywall
anchors (5 not provided) for additional support.
Wiring All wiring must take place inside junction box (not included)
Caution: Make sure power is off at fuse or circuit breaker box. Check power wires for damage
or scrapes. If power supply wires are within three inches of the LED driver, use wire suitable
for at least 90°C (194°F). Note: Most dwellings built before 1985 have supply wire rated to
60°C. Consult a qualified electrician to ensure correct branch circuit conductor before installing.
Step 2 Wiring fixture
A. Make all wire connections to appropriate wire. Secure with wire nuts (provided).
B. Connect the green wire from the fixture to the supply power source ground wire.
C. For none-dimming fixture. Connect the white wire from the fixture to the white (N) wire from
supply power source. Connect the black fixture wire to the black (L) wire from supply power
source.
D. For TRIAC dimming. Connect the white wire from the fixture to the white (N) wire from
dimming source per dimmer wiring instructions. Connect the black wire from the fixture to the
black (L) wire from dimmer supply power source per dimmer wiring instructions.
E. Do not mix wires. Pull on each wire lead to make sure connections are secure. Make certain no
bare wires are exposed outside of wire connectors. Tuck all connections neatly into the junction box.
Step 3 Mounting fixture
A. Install fixture pan (1) over the fixture mounting plate (2), aligning the side holes. Then use two
screws (4) to secure the fixture in place.
B. Install decorative outer band (7) to the fixture by aligning mounting holes on fixture
and band. Using allen wrench (9 provided), secure the frame to the fixture with
two set screws (8).
Step 4 Restore power at fuse or circuit breaker box