Limited Factory Warranty
AFX Inc. hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions for a period of 5 years
from date of shipment from factory. This warranty covers all component parts and extends only to replacement of defective fixture or components; it does not cover failure due
to improper installation, misuse, mishandling or damage incurred in transit.
Safety Precautions
Read all safety precautions and installation instructions carefully before installing or servicing this fixture. Failure to comply with these instructions could result in potentially fatal
electric shock and/or property damage.
It is recommended that a qualified electrician perform all the wiring. This fixture must be wired in accordance with all national and local electrical codes.
Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water.
This fixture is designed for use in a 120-277VAC / 60Hz fused circuit. This fixture is not compatible on a dimming circuit.
Make sure that the power source conforms to the requirements of the fixture. (See labels on the fixture housing).
To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding, there must be a separate ground
wire (green) contact between this fixture and the ground connection of your main power supply panel.
This fixture is intended to be used for general indoor lighting in dry or damp locations.
Disclaimer
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Canadian ICES-005 (B) / NMB-005 (B). These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiver antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult with the dealer or an experienced radio/TV technician for help.
Any modifications to this fixture may void the warranty and interfere with the safe operation of the luminaire.
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Assembly Instructions
Step 1 Preparing for installation
A. Disconnect electrical power at the fuse or circuit breaker box before installing or servicing any part of this fixture.
B. Carefully remove the fixture and parts bag from the carton.
C. Remove components from the parts bag.
D. Remove mounting bracket (1) from the fixture (3) by removing two screws (4).
E. Install mounting bracket (1) to the 3/0 or 4/0 junction box (not provided) using two screws (2) to secure it.
Wiring All wiring must take place inside the junction box (not included)
Caution: Make sure power is off at the fuse or circuit breaker box. Check power wires for damage or scrapes. If the power
supply wires are within three inches of the LED driver, use a wire suitable for at least 90°C (194°F). Note: Most dwellings
built before 1985 have supply wire rated to 60°C. Consult a qualified electrician to ensure correct branch circuit conductor
before installing.
Step 2 Wring fixture
A. Make all wire connections to appropriate wire. Secure with wire nuts (provided).
B. Connect the green wire from the fixture to the supply power source ground wire.
C. Connect the white wire from the fixture to the white (N) wire from the supply power source.
D. Connect the black wire from the fixture to the black (L) wire from the supply power source.
E. Do not mix wires. Pull on each wire lead to make sure connections are secure. Make certain no bare wires are exposed
outside of wire connectors. Tuck all connections neatly into junction box.
Step 3 Color changing temperature adjustment, CCT (if desired)
A. CCT switch is located behind the fixture. Adjust switch to desired temperature of 2700K, 3000K, 3500K, 4000K, or 5000K
as shown below. Note: Fixture is preset to 3000K from factory.
Step 4 Mounting
A. Install fixture (3) to the mounting bracket (1) by aligning both side holes with the bracket then using two
screws (4) to secure it.
Step 5 Power to the fixture can now be restored
2700K
•3000K
•3500K
•4000K
•5000K
View shown for reference only.
Individual models may vary. Note:
fixture can be horizontally or vertically
mounted on the wall.