Instructions / Assembly
V8PN Series LED Vanity Fixture
MODEL: V8PN260420LAJ, V8PN380430LAJ, V8PN500440LAJ D2 Fixtures
Page 1 of 1 8061130 R0
Safety Precautions
Read all safety precautions and installation instructions carefully before installing or servicing this fixture. Failure to comply with these instructions could result in
potentially fatal electric shock and/or property damage.
It is recommended that a qualified electrician perform all wiring. This fixture must be wired in accordance with all national and local electrical codes.
Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water.
D2 fixtures are designed for use in a 120-277V AC, 60Hz fused circuit and are compatible with 0-10 V dimmers. Make sure that the power source conforms to the
requirements of the fixture. (See labels on fixture housing)
To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding, there must be a
separate ground wire (green) contact between this fixture and the ground connection of your main power supply panel.
This fixture is intended to be used for general indoor lighting in dry or damp locations.
Disclaimer:
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This
equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Canadian ICES-005 (B) / NMB-005
(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiver antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult with the dealer or an experienced radio/TV technician for help.
Any modifications to this fixture may void the warranty and interfere with the safe operation of the luminaire.
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Assembly Instructions
1. Preparing for installation
Disconnect electrical power before installing or servicing any part of this
fixture.
A. Remove all contents from packaging.
B. Remove the finial thumb screws (2) from ends of diffuser (1). Slide
diffuser (1) off of channel (5).
B. Remove wire way cover (4) from channel (5) by removing 2 screws (3).
C. Remove the appropriate knockout(s) for power supply entry.
D. Install junction box cover plate (6) to junction box with two #8 screws (7).
2. Fixture mounting
A. To locate, hold channel (5) up to the wall with power supply knockout
located over entryway for power supply wires. Mark the locations of the
mounting holes on the wall. Take the channel down and punch a small
hole into the wall at each location using a nail or an awl to see if there is
a wood joist. If there is a joist use a suitable wood screw (not included) to
mount the channel. Where there is no joist to screw into use a toggle bolt
(not included) of suitable length to mount channel securely to the wall.
Install junction box cover plate (6) (supplied). Proceed to step B before
final mounting.
B. Feed the black and white supply wires, and the green ground wire (8) into
the fixture through the open knockout hole. At this time you can finish
mounting the channel to the wall.
3. Wiring
Caution: Make sure power is off at fuse or circuit breaker box. Check power wires for damage or scrapes. If power supply wires are within three
inches of driver use wire suitable for at least 90°C (194°F). Note: Most dwellings built before 1985 have supply wire rated to 60°C. Consult a
qualified electrician before installing.
A. This unit will not operate properly unless connected to a “grounded” electrical circuit. Electrical shock, overheating, low or no light output, and
shortened lamp life can result if proper grounding is not done.
B. Using wire connectors, connect white supply wire to white driver lead. Connect black hot supply wire to black driver lead. Connect ground
supply wire to green ground wire. Do not mix wires. Pull on each wire to make sure connections are secure. Make certain no bare wires are
exposed.
C. The LED driver can be dimmed with 0-10V dimming controls. Locate low voltage dimming control wires (purple and grey) and make
appropriate connections. For Non-Dimming applications, leave the dimming control wires, (purple and grey) capped.
D. Connect the LED’s to the driver by plugging the connector ends (9) together. Install wire way cover (4) by placing it over the channel and
fastening with 2 screws (3).
4. Color Changing Temperature Adjustment, CCT (if desired)
A. Set the two switches on each LED strip for the desired color temperature as shown in the above illustration. Note: Fixture is preset to 3500K
from factory.
5. Diffuser mounting
A. Slide diffuser (1) over channel assembly and align holes in diffuser with holes in end caps of the channel assembly (5). Insert finial thumb
screw (2) at each end and tighten.
Power to the fixture can now be restored.
Limited Factory Warranty
AFX Inc. hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions for a period of 5 years from date of
shipment from factory. This warranty covers all component parts and extends only to replacement of defective fixture or components; it does not cover failure due to improper installation,
misuse, mishandling or damage incurred in transit.