Calibrating Temperature
PFadvantage
(Harvest Mode)
Ag Leader Technology
September 2003
3-6
Step Action
1 Use the UP or DOWN ARROW keys to set the actual temperature.
2 Press the PERFORM CAL key to calibrate the temperature.
3 Press the ACCEPT key to accept the calibration.
4 Press the EXIT key once you have finished.
NOTE:
For accurate moisture readings, it is more important that you not
change the temperature calibration while harvesting. The temperature
reading does not have to be exactly right for correct moisture readings.
Therefore, after you calibrate temperature, leave it at that setting.
It is best to calibrate the temperature when the combine has been sitting
in a constant temperature for several hours. If the combine has sat
overnight, the moisture sensor may be cooler than the air temperature
because the air can warm much more quickly than the sheet metal of the
combine.
Upon pressing PERFORM CAL, the monitor automatically adjusts the
“Temperature Offset” number so that the “Measured Temperature” is
equal to the “Actual Temperature”.
* * *