Operator`s manual

PFadvantage
Calibrating Moisture
Ag Leader Technology
(Harvest Mode)
September 2003
3-11
Step Action
1 Use the UP or DOWN ARROW keys to set the grain. Press the
ENTER MOISTURE key.
2 Refer to the next screen and change the load (and field if necessary)
to the load that has an actual moisture. Use the UP or DOWN
ARROW keys to change the field or load, depending on which is
selected.
You must have either the field or load line selected (rectangular box
surrounds line) before you can change a field or load. To select
either field or load, press the key to the right of the field or load line.
3 Press the key to right of the “Actual Moisture” line to select that
line.
4 Use the UP or DOWN ARROW keys and enter the actual moisture
for the load.
5 Press the PERFORM CAL key. Press the ACCEPT key.
6 Press the EXIT key once you have finished.
NOTE:
Upon pressing PERFORM CAL, the monitor automatically adjusts the
“Moisture Offset” number so that the “Average Moisture” is equal to
the “Actual Moisture”.
Every time you calibrate moisture, the monitor will adjust the moisture
for all loads of that grain type.
* * *