Operator`s manual

Flexicoil Flexcontrol
PFadvantage
Application Rate Mode
Ag Leader Technology
September 2003
2-80
Setup for
Flexcontrol
controller
A separate configuration of settings should be created for every product
applied. A maximum of 16 different configurations can be created. The
screen below illustrates two configurations set up for the Flexcontrol
controller.
1. Press SETUP key. Press APP RATE CONFIG key. A screen
similar to the one below should appear:
APP RATE CONFIG
PRODUCT CONTROLLER CHANNEL
Fertilizer 1 Flexcontrol Air Tank 1
Fertilizer 2 Flexcontrol Air Tank 2
EDIT
SETTINGS
CREATE
NEW
DELETE
EXIT
1. Press CREATE NEW key to set up a new configuration or select an
existing configuration and press the EDIT SETTINGS key. A new
screen appears with the following settings. Select each setting and
press EDIT key to change the settings.
Controller Make: Set to FLEXICOIL.
Controller Model: Set to FLEXCONTROL
Product: Press EDIT key. You can select an existing product and
press ACCEPT key or create a new product by pressing CREATE
NEW key. Press EDIT NAME key and enter name of product.
Use Left or Right Arrow keys to select a character. Use Up or
Down Arrow key to change the character. To erase a character in
the name, highlight that character and use UP or DOWN ARROW
key to scroll to the blank space between "9" and "A". Set every
character and press ACCEPT key twice.
Units: Set to Units/Acre of application. Set to POUNDS if
applying fertilizer. Set to GALLONS if applying liquid.