Owner manual

7
3
5
2
8
1
6
4
SHURflo Model No: 8007-594-838
12 Volt Pump
Drive Assembly
Valve Assembly
Check Valve Kit
Switch Assembly
Upper Housing
Pkg. (4) Grommets
94-385-03
94-395-06
94-390-05
94-374-05
94-375-05
94-379-00
NUMBER
MFG PART
5168762
5168761
5168760
5168759
5157207
5157114
5084089
5075019
Part Number
FIMCO
5
8
7
6
No
Item
1
3
4
2
1
1
1
1
1
1
1
1
Qty
Diaphragm
Rocker Switch
Description
30.10
17.60
39.11
10.25
6.99
25.44
17.85
2.99
Price
List
After Spraying
After use, fill the sprayer tank part way with water. Start the
sprayer, and allow the clear water to be pumped through the
plumbing system and out through the spray nozzles.
Refill the tank about half full with plain water and use a
chemical neutralizer, such as 'Nutra-Sol', or equivalent, and
repeat cleaning instructions above. A mix of water and
some good quality dish detergent would be a sufficient
alternative.
Flush the entire sprayer with the neutralizing/cleaning agent,
then flush out one more time with plain water. Follow the
chemical manufacturer's disposal instructions of all wash or
rinsing water.
For the boom, (if applicable) remove the tips and screens
from the nozzle assemblies. Wash these items out
thoroughly. Blow the orifice clean and dry. If the orifice
remains clogged, clean it with a fine bristle (NOT WIRE)
brush, or with a toothpick. Do not damage the orifice. Water
rinse and dry the tips before storing.
WARNING: Some chemicals will damage the pump
valves if allowed to soak untreated for a length of time!
ALWAYS flush the pump as instructed after each use.
Page 2
Winter Storage
Drain all water out of your sprayer, paying special
attention to the pump, handgun, and valve(s). These items
are especially prone to damage from chemicals and
freezing weather.
The sprayer should be winterized before storage by
pumping a solution of RV antifreeze through the entire
plumbing system. This antifreeze solution should remain in
the plumbing system during the winter months. When
spring time comes and you are preparing your sprayer for
the spray season, rinse the entire plumbing system out,
clearing the lines of the antifreeze solution. Proper care
and maintenance will prolong the life of your sprayer.
Troubleshooting the Pump:
Pump will NOT run:
- Check inline fuse on the wires on the pump. (if
applicable)
- Make sure on/off switch is in the 'on' position (-).
- Make sure you 12 volt source (battery) is fully charged.
- Insure a tight connection at the battery clips.
If none of the above will work, try pulling the wires off the
pressure switch, and short them out. If your pump runs
when you do this, you know you will need to replace
your pressure switch.
Pump runs, but does not prime:
- Check line strainer (screen) in the tank, connected to
the bottom of the intake tube. Periodically take the
screen at this location out and clean it.
- Make sure the bypass line valve is closed, to allow the
pressure to build up in your system. (If equipped with
bypass)
- Unscrew the head portion of your pump and remove the
check valve assembly from inside. You need to make
sure the O-Ring comes out with this piece as well. (See
the exploded view to help identify these components)
These pieces can be cleaned which, in most cases, will
help restore some, if not most, of your prime. Soak this
check valve in a solution of hot, soapy water. A good
name-brand dishsoap works well for this. A little bit of
'scrubbing' with perhaps an old toothbrush may be
required to actually break up any build-up that may be on
the check valve. Rinse off the pieces and replace them
back into your pump. Reassemble the pump. Hook it
back up and test.