Aga 30AIM 115V ACIM-15 For models with serial number below 20070608001 Installation Operation & Maintenance Instructions
Starting Out Remove Packaging Your ice machine has been packed for shipment with all parts that could be damaged by movement securely fastened. Before installing the ice machine, be sure all packing materials and tape have been removed. Important Save the carton packaging until your ice machine has been thoroughly inspected and found to be in good condition. If there is damage, the packaging will be needed as proof of damage sustained in transit. Installation Select Location . . . . . . . . . . . . . . .
Installation Select Location The proper location will ensure peak performance of your ice machine. Choose a location away from heat and out of direct sunlight. Best performance will be maintained when installed within the following parameters: Ideal Ambient Temperature Range* built-in 55-80°F 55-90°F freestanding * Ice Machine will not perform correctly in ambient temperatures less than 55°F.
Installation: Drain Plumbing Drain Plumbing Your ice machine uses a gravity drain, (figure 1) that requires 5/8" I.D. tubing from the back of the ice machine to a plumbed connection to a sanitary sewer. Remove the access panel to plumb in drain connection. Gravity drain location for built-in units can be within the area shown in figure 3. An optional drain pump, (figure 2) can be purchased for your ice machine if a gravity drain is not accessible.
Water Supply Water Supply This ice machine must be connected to a potable, active cold water supply line delivering water pressure at a minimum of 20 psi and maximum of 120 psi. • Water connection is made through a right angle garden hose fitting. See garden hose fitting for detailed instruction sheet. • A water filter is recommended for this unit. A quality filter can remove particles as well as remove taste and odors from water. Do not use any thread sealers. • Softened water is not recommended.
Caring for Your Ice Machine Operation Normal Responsibilities of the Owner Your ice machine is unique in forming ice. It uses fractional freezing to form a slab of ice that is clear and has less mineral content than the water it is produced from. This is accomplished by running water over the cold evaporator plate which gradually freezes the water to produce the ice slab. Mineral deposits are left in the reservoir.
Caring for Your Ice Machine Cleaning Your Ice machine 8. Remove the distributor tube, hose clamp, hose and its rubber ends. 9. Thoroughly clean the inside of the distributor tube and the spray holes. You can use the same cleaning solution as before and an old toothbrush to reach the inside of the distributor tube. The impurities will regularly (at the very least, annually) need to be cleaned of this build-up, depending on use and water hardness.
Things to Remember Things to Remember • Allow your ice machine to run for 24-48 hours to accumulate ice in ice machine's bin. • Keep your ice machine clean for proper ice quality, production, and unit life. • Room and water temperatures will greatly affect the output of ice in your unit (see table). Ice will also melt away, especially at the start of an empty bin, but will slow down as ice accumulates.
Obtaining Service Before Calling for Service Before calling for service, check the following items: • Make sure unit is plugged into outlet. • Check the outlet for power. Test outlet with lamp to make certain outlet has power. • Make sure ice machine's switch is in the "ON" position. • Make sure that there is cold water supplied to the ice machine. • Make sure drain plug on bottom of reservoir is inserted. • Make certain unit is level from front to back and side to side. 2.
Troubleshooting One Problem Possible Cause Correction Unit does not operate. The unit is unplugged. Breaker is tripped or fuse is blown. Plug in the unit. Reset breaker or replace fuse. Check to make sure there is not a short in the electrical circuit. Set the rocker switch on the grille of the ice machine to the "ON" position. Ice machine selector switch is in the "OFF" position. Unit operates but does not produce any ice. The unit has just been started and it has been less than 6 hours.
Trouble Shooting Two Problem Possible Cause Correction Ice cubes are too small (less than 1/2 inch thick). Low ice consumption. Ice is slowly melting in the ice bin and will affect the size of the ice cube. This is normal operation. When the ice bin needs to be replenished, cubes will return to regular size. Make sure that the reservoir drain plug is installed properly. Check the water line to the unit to make sure there are no restrictions or kinks in the line.
Trouble Shooting Three Problem Possible Cause Correction Ice is not clear. Low water level in reservoir. Make sure that the reservoir drain plug is installed properly. Check the water line to the unit to make sure there are no restrictions or kinks in the line. Check all filters to make sure they are not restricted or plugged. Make certain that water line is not connected to the water softener. Move the unit to an area where room temperature is above 55 deg. F. Softened water supply.
Troubleshooting Four Problem Possible Cause Correction Ice cubes are sticking together. Ice consumption is low. Use the ice in the bin frequently. Ice will stick together if left in insulated bin over long periods of time. Move the unit to an area where temperature is below 90 deg. F. Room temperature is too warm. Ice level is too high. The ice machine is not level. Room temperature is too warm. Ice deflector is not in place or secured properly. Bin level sensing tube needs adjusted.
Warranty Household Refrigeration Products Limited Warranty Entire Product - Limited One Year Parts and Labor Warranty. Aga Ranges warrants that it will supply all necessary parts and labor to repair or replace in the end user's home or office, any component which proves to be defective in materials or workmanship, subject to the condition and exclusions stated below, for period of one year from date of purchase by the end user.
Notes All specifications and product design subject to change without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, replacements or compensation for previously purchased products.
Aga Ranges/Refrigeration Products Division P . O . B o x 41009278 Rev A 9 9 7 • R i c h m o n d , I n d i a n a • 4 7 3 7 5 • U S A • 1 . 8 0 0 . 2 4 3 .