Specifications

FM774/0708 BOOK 2 22
WW SERIES
2000 - 2005
Wall Control : WW Controller (SP3225)
Communication Board : WW BMCU (SP3227)
Compatible Roof Unit: Modular R/U (SP3000)
Control Cable: a) 7-pin 17vdc pre-terminated (SP5200) connection between
R/U and BMCU board.
b) 7-pin 14vdc pre-terminated (SP5200) connection between
BMCU and keypad.
c) 4-pin 14vdc pre-terminated (SP5202) connection between
BMCU and keypad for temperature sensing.
d) 8-pin pre-terminated (SP3229) connection to remote receiver
board.
Fan Motor: 600W, 750W, 1000W
Drainage: Counterweight Drain Valve (SP2040)
Pump: 240V pump
Solenoid: 24V solenoid
Modes of Operation
FAN - ventilation with fresh air.
EXHAUST - to extract air.
COOL - operates pump & fan for cooling.
AUTO - control unit to maintain constant pre-set temperature
TIMER - WAKE/SLEEP countdown timer to switch unit on or off
after timed inte
rval.
DAILY ON / DAILY OFF TIMERS
Fan Speeds: 100 speeds in all modes
Other Features:
Automatic wash and flush functions in Cool mode.
Temperature sensor in keypad - Current room temp displayed when in
standby mode.
Variable drain cycle – 1 to 24 hours.
Keypad reset button.
Digital display.
Time display.
WW Keypad
Back of WW Keypad WW BMCU Board
9V Battery
9V Battery Snap
5A Fuse
Roof Unit KDU Remote KDU
Temp. Sensor