Proudt Brochure
4
AGA Dual Control 3-Oven Cast Iron Range – Natural Gas
Model # ADC3G
External Venting
DOWNWARD RUNS UP TO 11
3
/4”(300mm) BELOW THE APPLIANCE ARE ALLOWED, PROVIDED ONLY
ONE BEND IS USED.
DOWNWARD RUNS USING 2 BENDS ARE NOT ALLOWED.
Fig. 11 DESN 516849
18
157
1
/2”
(4m) MAX.
11
3
/4”
(300mm)
MAX.
157
1
/2”
(4m) MAX.
Flue System
The ue system must be installed in
accordance with the federal, state and
local codes.
Products of combustion discharge is by a
fan powered ue pipe of 2" (50m diameter
which can reach up to 13’ (4 metres) in
length through a maximum of 4 x 90°
bend. Exits from the appliance can be from
rear, LH or RH sides. (See Figs. 8 and 9).
The ue pipe should protrude through
the outside wall xing plate by 1” (25mm)
(See Fig. 6).
Terminal Position
The minimum acceptable spacings from
the terminal to obstructions and ventilation
openings are as shown in Fig. 7.
Where the terminal is tted within 23
⅝" (600mm) below plastic guttering an
aluminium shield 39 ⅜” (1000mm) long
should be tted to the underside and
immediately beneath the guttering or
eaves.
Where the terminal is tted within 17 ¾"
(450mm) below eaves or painted guttering
an aluminium shield 29 1/2 (750mm) long
should be tted to the underside and
immediately beneath the guttering or
eaves.
Terminal Protection
A terminal guard is supplied with the range
and must be tted, if ue termination is
less than 78 ¾" (2 metres) above ground
level, or subject to damage.
When tted, it must be positioned to
provide a minimum of 2" (50mm) clearance
from any part of the terminal and be
central over the terminal.
Position Spacing
Minimum
inch (mm)
A Directly below an openable
window, air vent, or any other
ventilation opening
11¾" (300)
B Below gutter, drain/soil pipe
3" (75)
C Below eaves
7⅞" (200)
D Below a balcony or car port roof
7⅞" (200)
E From vertical drain pipes
and soil pipes
5⅞" (150)
F From internal or external corners
11¾" (300)
G Above adjacent ground
or balcony level
11¾" (300)
H From surface facing the terminal
23⅝" (600)
I Facing terminals 47¼"
(1200)
J From opening (door/window)
in car port into dwelling
47¼"
(1200)
K Vertical from a terminal
59" (1500)
A Horizontally from a terminal
11¾" (300)
Fig. 9
Specications are subject to change without notice. Visit www.aga-ranges.com for the most up-to-date information.
DOWNWARD RUNS UP TO 11
3
/4”(300mm) BELOW THE APPLIANCE ARE ALLOWED, PROVIDED ONLY
ONE BEND IS USED.
DOWNWARD RUNS USING 2 BENDS ARE NOT ALLOWED.
Fig. 11 DESN 516849
18
157
1
/2”
(4m) MAX.
11
3
/4”
(300mm)
MAX.
157
1
/2”
(4m) MAX.