Hanwood Wood Stove (Smoke Exempt) This appliance is hot while in operation and retains its heat for a long period of time after use. Children, aged or infirm persons should be supervised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled. When using the stove in situations where children, aged and/or infirm persons are present a fireguard must be used to prevent accidental contact with the stove.
TABLE OF CONTENTS PAGE NO. 1. Installation & Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2. General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Fire Cement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION & OPERATING INSTRUCTIONS area unless it is used in an "exempt" appliance ("exempted" from the controls which generally apply in the smoke control area). NOTE: Please note that it is a legal requirement under England & Wales Building Regulations that the installation of the stove is either carried out under Local Authority Building Control approval or is installed by a Competent Person registered with a Government approved Competent Persons Scheme.
PRE-INSTALLATION a zone of low pressure over the terminal. A suitable anti-down draught terminal or cowl will usually effectively combat direct down blow but no cowl is likely to prevent down draught due to a low pressure zone. (See Fig.1) Before using the stove for the first time all remaining stickers must be removed, all accessories must be removed from the ashpan, check if any items have become dislodged during transport.
Air vents traversing cavity walls should include a continuous duct across the cavity. The duct should be installed in such a manner as not to impair the weather resistance of the cavity. Joints between air vents and outside walls should be sealed to prevent the ingress of moisture. Existing air vents should be of the correct size and unobstructed for the appliance in use.
Where such an installation exists, a test for spillage should be made with the fan or fans and other appliances using air in operation at full rate, (i.e. extraction fans, tumble dryers) with all external doors and windows closed. If spillage occurs following the above operation, an additional air vent of sufficient size to prevent this occurrence should be installed. FLOOR PROTECTION The product must be placed on a non combustible hearth in accordance with UK Building Regulation part ADJ.
STOVE DIMENSIONS Fig 3 TECHNICAL DATA Fuel Wood Nominal Output - Room 9kW Typical refuelling intervals to obtain nominal outputs 1 hour Flue Gas Mass Flow 6.7 g/s Flue Gas temp at Nominal Output 326oC Gross Weight: 172 kgs Flue Outlet: 150mm Log Size: 500mm This appliance has been tested in accordance with BS EN 13240 NOTE:A suitable chimney (minimum profile, chimney draft, tightness, etc) is a basic condition for the proper functioning of fireplace stoves.
AIR CONTROLS RE-FUELLING This stove is fitted with one air control, this control operates both the primary and secondary flow to the stove. The control is located in the centre of the stove under the door, push the control to the right to open and to the left to close. When the control is in the mid position primary air is fully closed. When refuelling, always refuel onto a bed of glowing embers, riddle gently if necessary.
IMPORTANT - DAMAGE CAN OCCUR TO THE FIREBED AND GRATE ASSEMBLY IF THE ASHPAN IS LEFT TO OVER FILL. IMPORTANT NOTES Now that your stove is installed and no doubt you are looking forward to many comforts it will provide, we would like to give you some tips on how to get the best results from your stove. MAINTENANCE CREOSOTE - Formation and Need for Removal When some fuels are burned slowly, they produce tar and other organic vapours, which combine with expelled moisture to form creosote.
3. Lay some firelighters on the grate with two handfuls of kindling. The kindling must be cut into thin lengths and laid across each other in layers to allow for a quick lightup. Ignite the firelighters and close the door. 12. Avoid contact with appliance when in use as the stove reaches very high operating temperatures. 13. This appliance should be regularly maintained by a competent service engineer. Use only replacement parts recommended by AGA.
CO ALARMS GLASS Building regulations require that whenever a new or replacement fixed solid fuel or wood/biomass appliance is installed in a dwelling a carbon monoxide alarm must be fitted in the same room as the appliance. Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50202:2012 and from the alarm manufacturers instructions. 1. How to clean: The glass will clean itself when there is sufficient heat generated by burning fuel.
EXPLODED VIEW 11
PARTS LIST Exp. View No. Part Code Exp. View No. Part Code Exp. View No.
NOTES 13
NOTES 14
AGA, Station Road, Ketley, Telford, Shropshire, TF1 5AQ, UK 15 N00643AXX Rev 001 DP26/11/14