User Manual

10
Installation Guide
Please refer to the Total Control or Dual Control
installation guide for product dimensions following
the Hotcupboard instructions.
Electrical Connection
Electrical grounding is required on this
appliance.
DO NOT connect to the electrical supply
until the appliance is permanently
grounded.
This appliance must be connected to a
ground metallic permanent supply or wire
lead on the appliance.
Failure to follow these instructions could
result in death or serious injury.
Using Left Hand Side Flue Vent
Option - AGA Dual Control 5
Oven Gas Power Flue
When installing a
AGA Dual Control 5 Oven Gas
Power Flue where the cooker flue vent pipe exits to the
left, it will be necessary to use the off set flue pipe
adaptor (supplied with the installation kit). The adaptor
must be positioned at the cooker left hand flue exit to
allow the flue tube to pass behind the hotcupboard. (See
Figs. 6 and 7).
Always fit the offset elbow in a position that will not
create a water/grease trap.
Off set flue pipe adaptor
Pressure drop is equal to a 90° bend
Fig. 6
Fig. 7
General Installation
Requirements
The installation of the range must be in accordance with
the relevant requirements of the local Wiring and
Building Regulations. It shuld be in accordance also with
any relevant requirements of the local or state codes.
In your own interest and that of safety to comply with the
law, all appliances should be installed by an authorized
AGA distributor in accordance with the relevant
regulations.
Use these instructions when making the
electrical connection.
This appliance must be supplied with a 240V 60Hz
power supply and connected to a properly grounded
branch circuit protected by an appropriate circuit
breaker.
At 240 Volts the appliance has a maximum load of
12.5 amps.
The rating plate can be found on a pull out plate located
at the lower front of the appliance. Electrical hook-up
must be done by a licensed electrician. This appliance
must be installed according to regional codes, or in the
absence of regional codes, the National Electrical Code.
The power cord on the appliance is fitted with a
standard 3 conductor NEMA type 6 -20 P plug, and
should be plugged directly into a matching receptacle
(matching receptacle 6-20R) Do not cut or remove the
grounding prong from this plug.
An electrical socket (receptacle) must be provided within
5 feet of the left hand side of the appliance and easily
accessible for the user to disconnect. Do not position
the socket over the appliance. Do not use an extension
cord with this appliance.
Fig. 8