Owner's Guide

7
7” diameter
Max: 1.85 kW
Boost: 3.0 kW
7” diameter
Max: 1.85 kW
Boost: 3.0 kW
10” diameter
Max: 2.3 kW
Boost: 3.7 kW
7” diameter
Max: 1.85 kW
Boost: 3.0 kW
6” diameter
Max: 1.4 kW
Boost: 2.2 kW
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
HE-2
Cooking zone
Minimum Pan Diameter
(Pan base) inches (mm)
Front left
4 ¾(120)
Rear left
5 ½ (140)
Centre
8 ¼ (160)
Rear right
5 ½ (140)
Front right
5 ½ (140)
Fig. 2.4
Fig. 2.5
Fig. 2.6
The very best pans have bases that are very slightly curved
up when cold (Fig. 2.4). If you hold a ruler across the bottom
you will see a small gap in the middle. When they heat up the
metal expands and lies at on the cooking surface.
Make sure that the base of the pan is clean and dry to prevent
any residue burning onto the cooktop panel. This also helps
prevent scratches and deposits.
Always use pans that are the same size as (or slightly larger
than) the areas marked on the cooktop. Using a lid will help
the contents boil more quickly.
n
Always take care before touching the surface, even
when the cooktop is turned o. It may be hotter than
you think!
Cooktop control indications &
warnings
The induction cooktop comprises of ve cooking zones
containing induction elements with dierent ratings and
diameters (Fig. 2.5) each with a pan detector and residual
heat indicator, and a cooktop control display.
The cooktop control display (Fig. 2.6) informs you of the
following induction cooktop functions:
Pan Detector
H Residual Heat Indicator
A Automatic Heat-up
L Child Lock
L1/L2 Low Temperature/Simmer Setting
P Power Boost Setting
ON Advises user one or more zones are active
Pan detector,
n
IMPORTANT: After use, switch o the cooktop
element by its control and DO NOT RELY on the pan
detector.
If a cooking area is switched on and there is no pan in
place or if the pan is too small for the cooking area, then no
heat will be generated. The symbol [ ]will appear on the
cooktop control display; this is the “pan-missing symbol”.
Place a pan of the correct size on the cooking area and the
[ ] will disappear and cooking can begin. After 10 minutes
without detecting a pan the cooking zone will switch o
automatically.
Table 2.1 shows the minimum pan sizes recommended for
each cooking zone.
NOTE: Using pans with a base diameter smaller than those
recommended will result in a power reduction.
Table 2.1