OPERATING INSTRUCTIONS
Energy Option Selections
Hi-temp
When HI-TEMP option is selected, the dishwasher heats
water in the main wash to approximately 140°F (60°C).
This increase in water temperature helps dishwasher
detergent remove food, grease and soil from dishes more
effectively and aids in drying. HI-TEMP option can only be
used with AUTO, HEAVY, NORMAL and UPPER cycles.
Sanitize
To sanitize your dishes and glassware, select the SANI-
TIZE option. This option heats the water temperature in the
 nal rinse to 157°F (69.4°C) and maintains that tempera-
ture for 7 minutes. SANITIZE is available in Auto, Heavy,
and Normal cycles. Only these sanitization cycles have
been designed to meet NSF requirements.
The cycle time will be extended until the proper water tem-
perature is reached. Washing action will continue during the
water heating delay. For best results, the incoming water
temperature should be at least 120°F (49°C).
If the SANITIZE option is selected, the pad illuminates with
a blue light. The sanitization criteria may not be satised if
there is an interruption of the cycle, a power failure occurs,
or if incoming water temperature is below 120°F (49°C).
Sanitize pad ashes at the end of the cycle if the NSF
requirements for sanitization are not reached.
Child Lock Controls/Air Dry
To prevent children from accidently changing the dishwash-
er cycle or starting the dishwasher, lock the dishwasher
controls by pressing the AIR DRY pad until “ ” shows in
the status window. The controls are locked and no new
selections can be made until the lock is released. To unlock
the controls, press the AIR DRY pad until “ ” disappears.
If child lock is activated the dishwasher will not work.
Max Dry
MAX DRY is available on Auto, Heavy, Normal, Upper and
Stemware cycles The cycle time will increase when MAX
DRY option is selected.
Operation Selection
Delay
The Delay Start option allows you to automatically delay
starting your dishwasher from 1 to 24 hours.
Press DELAY pad until the desired delay time shows in
the Status window then press START to con rm the delay
time. Press START again and close door to activate. Dis-
play will indicate the delay start time and will countdown
until cycle starts.
To cancel the DELAY option and begin the cycle before the
delay period is over, press the CANCEL pad and then the
START pad.
Start
To start a cycle, press the START pad once and close the
door.
Cancel
To cancel a cycle at anytime, open the door and press
the CANCEL pad until the 1 min drain feature is initiat-
ed. Close the door and the drain cycle will begin. You will
hear a tone for the start and completion of the drain cycle.
When the door is opened, the last cycle selected will be
displayed. If desired, a new cycle can now be selected and
upon closing the door the cycle will begin.
NOTE
Opening the door during normal operation will only pause
the selected cycle.