Installation Manual

6
GAS TOP BURNERS
This appliance is supplied set for Natural Gas (NG) at a pressure of 4” WC. It must be converted to run on LP Gas (Propane)
at a pressure of 10” WC.
NATURAL GAS
L.H.F. R.H.R. L.H.R. R.H.F.
BURNER TYPE ULTRA-RAPID RAPID SEMI-RAPID SEMI-RAPID
(WOK)
MAXIMUM HEAT 3.5 kW 3.1 kW 1.8 kW 1.8 kW
INPUT 12,000 Btu/hr 10,600 Btu/hr 6,150 Btu/hr 6,150 Btu/hr
INJECTOR MARKING 170 155 118 118
PRESSURE POINT POSITION: JUST BELOW HOTPLATE LEVEL ON REAR RIGHT HAND SIDE OF RANGE
PRESSURE SETTING:
4” w.g.
BURNER IGNITION: H.T. SPARK
PROPANE
L.H.F. R.H.R. L.H.R. R.H.F.
BURNER TYPE ULTRA-RAPID RAPID SEMI-RAPID SEMI-RAPID
(WOK)
MAXIMUM HEAT 3.5 kW 3.1 kW 1.8 kW 1.8 kW
INPUT 12,000 Btu/hr 10,600 Btu/hr 6,150 Btu/hr 6,150 Btu/hr
(250g/h) (221g/h) (128g/h) (128g/h)
(0.5l/h) (0.43l/h) (0.26l/h) (0.26l/h)
INJECTOR MARKING 105 94 72 72
PRESSURE POINT POSITION: JUST BELOW HOTPLATE LEVEL ON REAR RIGHT HAND SIDE OF RANGE
PRESSURE SETTING: 10” w.g.
BURNER IGNITION:
H.T. SPARK
ELECTRIC OVENS 240 VOLT 60 Hz SINGLE PHASE 30 AMP
TOP OVEN POWER RATING - 3.0 kW
LOWER OVEN POWER RATING - 0.9 kW
The data plate is located on a pull out plate, behind the plinth cover.
TYPICAL SECTION VIEW OF BURNER FLAMES:
TECHNICAL DATA
11
/
16
15
/
16
9
/
16
7
/
8
1
/
2
7
/
16
(11mm)
(17.5 mm)
(24 mm)
(14 mm)
(22 mm)
(12.5 mm)
L.H.F. HOTPLATE BURNER
R.H.R. HOTPLATE BURNER
L.H.R. & R.H.F. HOTPLATE
BURNER