Technical data

OVEN THERMOCOUPLE
Fig. 7 DESN 515277
NOTE: On AIMS controlled cookers the thermostat phial (probe) has
been replaced by an oven thermocouple sensor, which is fitted to the
PCB on the controls chassis. (See Fig. 2).
1. Feed the thermocouple sensor through the guide tube into the
Roasting oven.
2. Fit the thermocouple sensor to the support plate so that the sensing
tip is as shown in (See Fig. 7). DO NOT OVERTIGHTEN the clamp as
this may damage the sensor. Screw support plate to top of roast oven.
3. When assembling the controls chassis to the burner housing:-
Ensure that the thermocouple sensor goes through the notch in the
top rear of the panel, and that the sealed pot is below the notch (i.e.
sealed pot must not be trapped between mounting chassis and
mesh shield).
10
Fig. 8 DESN 515284