GC3 (THREE OVEN) WITH AIMS Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by AGA.
CONTENTS SECTION PAGE HEALTH AND SAFETY 3 INSTALLATION 4 LOCATION 4 TECHNICAL DATA - AGA GC3 5 TECHNICAL DATA - AGA GC3 (WITH MODULE) GC3M) 6 TECHNICAL DATA (CONTINUED) 7 FLUE SYSTEM 7 INSTALLATION PIPES 8 AIR SUPPLY 8 BAKING OVEN BAFFLE PLATE 8 ELECTRICAL 8 BURNER ASSEMBLY - AIMS CONTROL 9 WIRING DIAGRAM 9 ASSEMBLY OF BURNER - AIMS CONTROL 10 OVEN THERMOCOUPLE 10 TO TEST THE AIMS CONTROL HANDSET 11 COMMISSIONING 12 - 13 INSTRUCTIONS 13 BURNER CONTROLS 14 2
HEALTH & SAFETY Consumer Protection As responsible manufacturers we take care to make sure that our products are designed and constructed to meet the required safety standards when properly installed and used. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
INSTALLATION With specific exceptions, the installing of any type of AGA cooker is subject to the respective directions contained in current issue of The Building Regulations. In addition, Planning Permission may need to be obtained, which should be applied for separately. The complete range of AGA cookers are suitable for Natural or Propane gases only and cannot be used on any other gas. (IMPORTANT: See data plate which is situated on burner housing panel behind top left door).
TECHNICAL DATA - AGA GC3 Fig. 1 DESN 512841 B A B C D E F G H J K L M N mm 987 889 851 679 467 1035 41 1330 756 1125 73 39 3 P W 698 116 PLEASE NOTE: SIDE CLEARANCE W IS ALSO REQUIRED ON THE LH SIDE FOR THE BAKING OVEN DOOR. COOKER DIMENSIONS When surveying for a cooker installation the actual clearance required for the ‘body’ of the appliance should be increased overall by 10mm beyond the figures quoted above.
TECHNICAL DATA - 3 OVEN AGA WITH MODULE (GC3M) Fig. 1A - Gas Supply Connections (Approximate Positions) NOTE: 1/4” BSP to 15mm fitting provided.
TECHNICAL DATA (CONTINUED) AGA GC3 COOKER (AIMS) NATURAL G20 MAXIMUM HEAT INPUT Thermostat Bypass Size Main Burner Injector Pilot Injector Inlet Pressure (EU COUNTRIES ONLY) Burner Pressure 4.4 kW 110 400 7218 20mbar 10 mbar (4” w.g.) PROPANE G31 5kW (357g/h) 65 170 4209 37mbar 25mbar (10” w.g.
INSTALLATION PIPES Installation pipes should be fitted in accordance with current Gas Regulations. Pipework from the meter to the cooker must be of adequate size, cooker connection size of 15mm Dia. On completion test the gas installation for soundness and purge in accordance with the regulations in force.
BURNER ASSEMBLY - AIMS CONTROL Fig. 2 A - ON/OFF CONTROL KNOB B - TEMPERATURE CONTROL KNOB C - GAS COCK D - INLET PRESSURE TEST NIPPLE E - BURNER PRESSURE TEST NIPPLE F - FLUE SAFETY DEVICE G - AIMS CONTROL KNOB H - VIEWING WINDOW DESN 515489 WIRING DIAGRAM Fig.
ASSEMBLY OF BURNER - AIMS CONTROLS SEE FIG. 2 NOTE: Prior to assembly remove controls mounting bracket from burner housing. 1. 2. 3. 4. Fit gas cock to inlet supply pipe. Fit burner assembly to burner housing. Fix AIMS control mounting bracket to burner housing. Attach wiring to AIMS control board (See Fig. 3) and solenoid plugs onto solenoids. Fix wires to cable clamp. 5. WHEN FITTING AIMS CONTROL COVER: (a) Take care to route solenoid cables through notch at rear of cover.
DESN 515480 Fig. 5 TO TEST THE AIMS CONTROL HANDSET Fig. 6 DESN 515481 Handset to Base Unit Signal Check/Language Selection Complete the following procedure to check the handset is communicating with the base unit and to select language option. 1. Switch on the power supply to the cooker. Immediately, switch the control knob on the base unit back and forth between manual and AIMS setting until the blue neon flashes. 2.
COMMISSIONING CAUTION: BEFORE LIGHTING: ENSURE KNOB (A) IS IN THE OFF POSITION (SEE FIG. 8). ALSO ENSURE GAS SUPPLY TO COOKER IS ON, AND THE GAS SERVICE COCK (C) IS IN THE ON POSITION (SEE FIG. 2), AND THE ELECTRICAL SUPPLY TO THE AGA IS SWITCHED ON. LIGHTING PROCEDURE: SEE FIGS. 7 - 13. 1. The main burner gas flow is set with the ‘temperature’ knob (B) (See Fig. 7). First, ensure both knobs are turned fully clockwise.
COMMISSIONING (CONTINUED) 7. Check burner pressure as follows:Repeat instruction 6 on completely cold cooker with the pressure gauge fitted to the burner pressure test nipple (E). (See Fig. 2). Check that the burner pressure correctly corresponds with the table marked ‘TECHNICAL DATA ‘, (page 7). NOTE: IF FOR ANY REASON A GAS RATE CHECK IS REQUIRED. TURN OFF ALL OTHER APPLIANCES USING GAS AND USING THE GAS METER TEST DIAL AND STOPWATCH.
BURNER CONTROLS Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig.
For further advice or information contact your local AGA Specialist With AGA’s policy of continuous product improvement, the Company reserves the right to change specifications and make modifications to the appliance described and illustrated at any time Manufactured by AGA Station Road Ketley Telford Shropshire TF1 5AQ England www.aga-web.co.uk www.agacookshop.co.uk www.agalinks.