5. The Module plinth can now be levelled and fitted up to the main appliance. Position the Module plinth alongside the
AGA TC3/DC3 leaving no gap betweem the two plinths. (See Fig. 6).
When fitting the Module onto an AGA TC5/DC5 there should be a gap of
11
/64” (4.5mm) (See Fig. 5).
PLEASE NOTE: When fitting a Module plinth to an AGA TC5 or AGA DC5 the 2 adjustment screws should be screwed
in from the outside (until they are fully in). The screw heads will set a gap of
11
/64” (4.5mm) between plinths.
Fig. 5 DESN 516859
11
/64” (4.5 mm)
SCREW HEAD DEPTH
Check with a spirit level that the plinth is correct and using a straight edge check that both plinths are aligned along the
front face (using either front or rear plinth adjustment screw to alter alignment, if necessary).
Also check height differential between the Module plinth and AGA Total/Dual Control plinth is correct
3
/8” (11mm) (See
Fig. 6 or 6A). If necessary, use the adjusting studs in each corner to level the plinth. In extreme instances, shims may
be used underneath the plinths .
Fig. 6 DESN 516276
MODULE PLINTH
BASE
3
/8” 11mm
HEIGHT
DIFFERENTIAL
FOR AGA TC3/DC3 + MODULE ONLY
12