8. Check current is OFF.
Connect mains wire to terminal block at the rear of the cooker (See Fig. 9). Sufficient cable should be available to allow
cooker to be removed for service.
Electrical Connections
Electric Shock Hazard
Electrical grounding is required on this range.
Do Not connect to the electrical supply until the range is permanently grounded.
Disconnect the power to the junction box before making the electrical connection.
This range must be connected to a grounded, metallic, permanent supply or a grounding connector should be
connected to the grounding terminal or wire lead on the range.
Do Not ground to gas pipe. Failure to follow these instructions could result in death or serious injury.
l A four-wire single phase 240-volt, 60-Hz, AC-only electrical supply is required on a separate, 30-amperes circuit, fused
on both sides of the line.
l A time-delay fuse or circuit breaker is recommended.
l Local codes permit the use of a U.L.-listed, 250-volt, 30-amperes power cord (pigtail). This cord contains four No. 10
copper wires and matches a four-wire receptacle of type 14-30R shown in Fig. 9. Connectors on the appliance end
must be provided at the point the power supply enters the appliance.
Wire sizes (COPPER WIRE ONLY) and connections must conform with the rating of range (30- amperes).
l The wiring diagram is located on the back of the range.