15
TRANSMIT CHANNELS - TYPICAL SCENARIOS
Co-Location of AGD Detectors
Installing two or more AGD detectors e.g 306, 326 or 316, 326 on the same traic signal pole can result in
crosstalk and a degradation in performance if they are on the same frequency.
Please be mindful of additional AGD products located on the same pole or in the vicinity of any new installation.
Example 1: Standard crossing layout two AGD326 detectors
Equipment: 2 x AGD326 Pedestrian On-Crossing Detectors
Channel(s): 1 and 4
*Important information
AGD326 Pedestrian Detectors are shipped from the factory with dierent channel frequencies assigned to
dierent serial numbers, follow the guide below when selecting serial numbers at point of installation:
Channel 1
Channel 4
Up to 16m
4
3
2
1
Up to 16m
Up to 10m
2
1
4
3
Up to 16m
Up to 10m
Up to 16m
Up to 10m
MUST
DETECT
ZONE
Technical Resource
Serial Number Channel
0001 1
0002 2
0003 3
0004 4
0005 1
0006 2
0007 3
0008 4