Product Manual
AGD 326
AGD 326
PEDESTRIAN ON-CROSSING DETECTOR
AGD 326
PEDESTRIAN ON-CROSSING DETECTOR
AGD 326
PEDESTRIAN ON-CROSSING DETECTOR
16
TRANSMIT CHANNELS - TYPICAL SCENARIOS
Co-Location of AGD Detectors
Example 1: Standard crossing layout two AGD326 detectors alongside two radars
The devices numbered 1 to 4 are
representive of radar traic detectors,
these can be either AGD306, AGD326,
AGD316 or AGD318.
The tables right indicate suggested
channels for the products when the
configuration is as above.
Channel 1
Channel 4
Up to 16m
4
3
2
1
Up to 16m
Up to 10m
2
1
4
3
Up to 16m
Up to 10m
Up to 16m
Up to 10m
MUST
DETECT
ZONE
Technical Resource
No. AGD Product Channel
1 AGD316 Stopline Radar n/a
2 AGD326 Pedestrian Detector 1
3 AGD326 Pedestrian Detector 2
4 AGD316 Stopline Radar n/a
No. AGD Product Channel
1 AGD306 Traic Control Radar 1
2 AGD326 Pedestrian Detector 1
3 AGD326 Pedestrian Detector 2
4 AGD306 Traic Control Radar 2
No. AGD Product Channel
1 AGD318 Traic Control Radar 1
2 AGD326 Pedestrian Detector 1
3 AGD326 Pedestrian Detector 2
4 AGD318 Traic Control Radar 2