Product Manual

AGD 326
AGD 326
PEDESTRIAN ON-CROSSING DETECTOR
AGD 326
PEDESTRIAN ON-CROSSING DETECTOR
AGD 326
PEDESTRIAN ON-CROSSING DETECTOR
5
STEP 1 - MOUNTING
HEIGHT - The AGD326
radar has been designed
to operate at a mounting
height of between 2m-4m,
with an unobstructed
view of the detection zone
(optional height extension
bracket BR-129 is available
if required).
4m max
Detector mounted at 3m
2m min
STEP 3 - VERIFICATION AND
ADJUSTMENT - Confirm that
the radar is correctly aligned
by ensuring that targets are
reliably detected within the
specified detection zone.
Adjust if necessary and retest.
Once aligned correctly, ensure
that the mounting nut is
fully tightened and that the
detector is secure.
STEP 2 - DETECTOR
ALIGNMENT - The AGD326
should be mounted using
the supplied hardware.
Direct the radar to point at
the centre of the furthest
point of detection. On a
level carriageway, this
will typically result in
a declination angle of
approximately. 9 degrees.
Lightly tighten the
mounting nut to prevent
any movement.
Installation and Commissioning
PHYSICAL INSTALLATION
9ยบ
Channel 1
Channel 4
Up to 16m
4
3
2
1
Up to 16m
Up to 10m
2
1
4
3
Up to 16m
Up to 10m
Up to 16m
Up to 10m
MUST
DETECT