Product Manual

AGD 326
AGD 326
PEDESTRIAN ON-CROSSING DETECTOR
AGD 326
PEDESTRIAN ON-CROSSING DETECTOR
AGD 326
PEDESTRIAN ON-CROSSING DETECTOR
8
ELECTRICAL INSTALLATION
APPLYING POWER
Make sure the power supply is the correct voltage,
which can be found on the label on the unit.
• Connect the unit to the supply.
Once powered, the front and rear LEDs should flash
five times whilst the radar performs its self check
routines.
Upon power up, owing to the nature of the equipment’s
power supply, an initial current of up to 200mA can be
drawn and the supply should be fused as follows:
230V models: This product must be protected by a 3A
circuit breaker.
12/24V Models: This product must be protected by a 1A
circuit breaker or in-line fuse.
Typical Power Consumption
12Vdc - 84mA (peak 195mA)
24Vdc - 43mA (peak 95mA)
24Vac - 66mA (peak 115mA)
230Vac - 10.1mA (peak 20mA)
The installation of this equipment MUST conform to the latest edition of the IEE Wiring Regulations (BS7671).