RADAR COMMAND LIST
Command Type Function Default
Value
Min
Value
Max
Value
Units, Resolution or
Values
AGD Displays the product information and firmware /
software revisions
n/a n/a n/a Text Display
*BAUD ?/= Enquire / Set the baud rate of the radar. The
program is stored in non-volatile memory and is
used the next time the radar is powered on.
*BAUD =<baud>, <flow control>, <parity>,
<number of data bits>
e.g.*baud=115200,0,NONE,8
921600
Flow
Control 0
Parity ODD
Number of
data bits 8
2400 921600 Baud Rate Values: 2400,
4800, 9600, 19200, 38400,
57600,115200, 230400, 460800,
921600
Flow Control: 0=no control
1=flow control
Number of data bits 7,8
*CD ? Enquire the calibration date DD,MM,YYYY
*CRC32 ? Calculates and verifies the 32 bit CRC code and
data checksums
*CHAN ?/= Enquire / Set the transmit channel 3 1 4
1-4
1-24.075
2-24.175
3-24.125
4-24.225
(4 channel variant)
*CT ?/= Enquire / Set the co-ordinate type used in the
target detection messages
P P C P = Polar
C = Cartesian
*DIR ?/= Enquire / Set the radar direction mode
A
A R A= Advancing
R= Receding
B= Bi-Directional
N= No Detection
*ETPn
(n=1 or 2)
?/= /^ Enquire / Set an Event Trigger Point at a defined
range
20 6
(0 = off)
84
1 metre
*ETPnLST
(n=1 or 2)
?/= /^ Enquire / Set the optional Event Trigger Point
Low Speed Threshold
10 10 249
KPH
units change depending on speed
units (see *SU)
*ETPnHST
(n=1 or 2)
?/= /^ Enquire / Set the optional Event Trigger Point
High Speed Threshold
250 11 250
KPH
units change depending on speed
units (see *SU)
*ETPnDIR
(n=1 or 2)
?/= /^ Enquire / Set the optional Event Trigger Point
Direction.
NOTE: The *DIR command must also be set to
allow the required Event Trigger Point direction
otherwise the event will not be triggered.
B A R A = Approaching
R = Receding
B = Bi-directional
*ETPnLPT
(n=1 or 2)
?/= /^ Enquire / Set the optional Event Trigger Point
Low Threshold Power (target amplitude)
65
55 109 dB
(ref Target amplitude values in
Target Detect message)
*ETPnHPT
(n=1 or 2)
?/= /^ Enquire / Set the optional Event Trigger Point
High Power Threshold (target amplitude)
110 56 110 dB
(ref Target amplitude values in
Target Detect message)
*HBP ?/= Enquire / Set the heartbeat period 60
0 (off) 86400
1 second
*HELP Lists all commands along with command help
information
*HOLD ? / = /^ Enquire / set the hold time of the opto output.
Opto output is triggered on ETP1
0.5 0.1 10 seconds
*HR ? / = /^ Enquire / set the High Range threshold 85 20 85 metres
*HS ? / = /^ Enquire / set the High Speed Threshold 250 40 250 KPH
(Units change depending on
speed units (see *SU)
*HS ? / = /^ Enquire / set the High Speed Threshold 250 40 250 KPH
(Units change depending on
speed units (see *SU)