RADAR COMMANDS
RADAR COMMAND LIST
Command Type Function Default
Value
Min
Value
Max
Value
Units, Resolution or
Values
*IP ?/=/^ Not Currently Enabled
*LR ? / = /^ Enquire / set the Low Range Threshold 4 4 40 metres
*LS ? / = /^ Enquire / set the Low Speed Threshold 10 10 160 KPH
(Units change depending on
speed units (see *SU)
*MSG ?/= /^ Enquire / Set the message type displayed on
the output
2 2 4 2 = Target Detect Message
3 = Event Trigger Point
Message (only)
4 = Tracked Target Messages
(and event trigger point message
if event trigger point enabled)
*REBOOT ! Force a reboot of the radar
*SN ? Read the serial number of the radar
*TEXT ?/= Read / Write free form text to non-volatile
memory
*TEMP ? Reports the temperature measured inside
the radar
ºC
*VER ? Provides the product number, firmware
version and date
*SU ? / = Enquire / set the speed units used in the
messages.
K K M K = KPH
M = MPH
*THRESHOLD ? / = /^ Enquire / set the detection power threshold.
Caution: setting this value too high may make
the radar deaf. Setting it too low may make the
radar very noisy
85 55 120 dB