User Manual
Table Of Contents
- Table of contents
- About this manual
- Introducing the Drystar 5500
- Basic operation (operator mode)
- Advanced operation (Key-operator mode)
- Overview of Key-operator functions
- Stopping the printing process
- Viewing printer information
- Changing the configuration settings
- Printing images
- Saving the configuration settings
- Restoring the configuration settings
- Performing the calibration procedures
- Installation
- Quality control for general radiography applications (DT 2 B & DT 2 C)
- Quality control for mammography application (DT 2 Mammo) (optional)
- Controlling the Drystar 5500 via a remote PC (with browser)
- System description
- Preventive maintenance and replacements
- Troubleshooting
- Equipment information sheet
- Drystar media density response data
- Quality Control Charts
- Remarks for HF-emission and immunity
- Remarks for HF-emission and immunity
- This device is intended for operation in the electromagnetic environment given below. The user of the device should ensure that it is used in such an environment.
- This device is intended for operation in the electromagnetic environment given below. The user of the device should ensure that it is used in such an environment.
- This device is intended for operation in the electromagnetic environment given below. The user of the device should ensure that it is used in such an environment.
- This device is intended for operation in an electromagnetic environment in which the radiated high frequency disturbance variabl...
- Remarks for HF-emission and immunity
- Index
229
2900H EN 20071108 Equipment information sheet
DRYSTAR 5500/5503 REFERENCE MANUAL
Electrical connection
Operating voltage 100-120 V; 220-240 V AC
Rated current 4/2 A
Mains fuse protection
220-240 V operation 16/15 A slow blow, max.
100-120 V operation 16/15 A slow blow, max.
Mains frequency 50/60 Hz
Network connectivity
Ethernet / connectors
RJ45 twisted pair for 10/100Base-TX;
Serial RS232 connection
Network protocols (TCP/IP services) FTP, Telnet, HTTP, SNMP, LPD
Image formats
DICOM (Default)
TIFF
Power consumption - heat dissipation
During operation 450 W - 1620 kJ/h
In standby 200 W - 720 kJ/h
Peak power (absolute max. rating) 700 W - 2520 kJ/h
Protection against
Electrical shocks Class 1 (grounded)
Ingress of water IPXØ
Environmental conditions (operation)
Room temperature Between +15°C and +30°C
Relative humidity
Between 20% and 75%
Note: Films may not become wet!
Atmospheric pressure 70 kPa - 106 kPa