Service manual

Section I: Imagesetter
Diagnostics 3-37
Plate Overlap (108) 1080
PL-12 Rewind Lev (109)
Feed High Res (63)
Interpage High Res (64)
Feedcut High Res (65)
Plate Mode (67)
Cassette Parameters
The cassette parameters contain the customer settings for the five cassettes. Write
new values to the imagesetter by simply typing in a new value in the appropriate
parameter. Listed below is a typical Customers Cassette Parameters Menu:
Parameters No. 1 2 3 4 5
Density 1200 DPI (05) 220 873 840 175 175
Density 1800 DPI (05) 175 462 460 175 175
Density 2400 DPI (05) 150 300 404 175 175
Density 3600 DPI (05) 115 190 200 175 175
Media Left (08) 1902 2500 1809 1895 0
Media Type (14) 1 1 1 1 1
Punch Enable (22) 2 0 0 0 0
Media Width (27) 64800 57600 57600 57600 57600
Media Thickness (47) 4 4 4 4 4
Image Position (66) 540 540 540 540 540
Operational Statistics
Selecting OP Stats displays a dialog box that shows the operational statistics stored
in the imagesetter in OCP EEPROM. The software retrieves the parameters from
EEPROM after the menu is selected. The operational statistic values can not be
changed or cleared. A typical systems operational lifetime statistic menu is shown
below.
Operational (Lifetime) Statistics
Cuts : 147
Supply Punches : 124
Takeup Punches : 124
Media : 7131 (in tenths of feet)
Takes : 761
Spot Changer : 162
Elapsed Uptime : 2592:06 (Hr./Min.)