Service manual

Avantra 36/44 Service Manual
3-38 Diagnostics
Firmware Revisions
Selecting Firmware Revs displays a dialog box that lists the firmware revision levels
installed in the imagesetter currently connected.
Avantra Firmware Revisions
DEC Firmware (K4/K1 FlashROM : *
DSP Firmware (DEC FlashROM) : *
OCP Firmware (OCP FlashROM : *
OCP Download (OCP EEPROM) : *
Diagnostic Firmware (C9) : *
Correction Table Version-Type : *
Bridge/OLP (OLP FlashROM) : *
* The revision levels change from release to release.
Display Error Log
Selecting Error Log displays a dialog box that shows a scrolling list of errors logged
in the imagesetter. The error log contains the last 64 errors (both boot and applica-
tion) encountered by the system. If the system supports real-time clock then only
the last 30 errors will be displayed. The error codes are in DEC EEPROM. The soft-
ware retrieves the error log from EEPROM upon entering this menu selection. Clear
the error log by pressing ALT C. A typical error log is shown below.
AVANTRA ERROR LOG
Index Error Date* Time* Description
====================================================================
000 037 11-21-96 10:16 Output Cassette Jam/Blocked Sensor
001 01 11-07-96 15:50 Carriage Jam
* If the system does not support real-time clock then the Error Log will display “Media” instead of date