Local Modem
Configuration:
The recommended local modem connected to the PC is also a GVC 2400BPS Fax/Modem. If
the remote and local modems are the same, command compatibility, data compression, and
data correction features should operate properly. Other modems can be used but they must
meet the requirements in Table 3-5 and Table 3-6.
Table 3-5
Table 3-6
After the modem has been configured, store the settings in the active configuration profile
(usually 0) with the following command:
AT&W0
Hardware Connection:
After the modem has been configured, perform the following procedures:
1. Connect the 9-pin end of the modem serial cable to the appropriate serial port of the
PC.
2. Plug the DIN connector into the modem.
NOTE: Depending on the PC used, a 9- to 25-pin adapter cable may be neces-
sary to connect the modem cable to the PC's serial port.
COMMAND DESCRIPTION
E0 Echo Off
V1 Word Responses
&D0 Modem Ignores DTR Ready Signal
N0 Disables Auto-mode detection;
Connection Speed Specified by
Register S37
&K3 Enables RTS/CTS Flow Control
&Q5 FAX Modem Negotiates Error
Correcting Connection
\N3 Selects Auto-reliable Mode
REGISTERS
S0=1 Auto Answer Enabled
S7=120
Wait Time for Remote Carrier
(2 minutes)