Service manual

Section II: Bridge
Diagnostics 3-5
3.1.4 Bridge State Responses
Bridge state responses display on the terminal when entering or changing an inter-
nal state. An “r” precedes a bridge state. Valid bridge states follow.
3.1.5 Bridge Error Codes
Bridge error codes display on the terminal when an error condition occurs. An “e”
precedes an error code. A list of bridge error codes follows.
r01 Error
r02 Ready
r03 Busy
r40 Command Acknowledge
r41 Invalid Mode
r42 Parameter Out Of Range
r43 Invalid Command
r44 Command Abort
e11 Center not reached
e12 Processsor not reached
e13 Center not cleared
e14 No lower encoder
e15 No upper encoder
e16 No media to take
e17 Buffer entry sensor not reached
e18 Buffer purchase sensor not reached
e1A Bridge not cleared
e1B Processor not reached by buffer
e1C Buffer clear position not reached
e1D Buffer not cleared
e1E Bridge not reached by buffer
e1F Buffer carriage home error
e20 Shuttle - Bridge mode not reached
e21 Shuttle - Cassette mode not reached