Installation guide
38  
Chapter 2: Connecting and Configuring Hardware
To connect multiple frames
To connect multiple frames
As many as eight 16700B’s and/or 16702B’s with expander frames may be 
connected together. To connect multiple frames you need to order 16700B 
option #012 and/or 16702B option #012.
NOTE: The multiframe module requires software Rev. A.02.00.00 or higher. Agilent 
16700B and 16702B logic analysis systems ordered with the multiframe option 
installed will have the current operating system software installed.
1 If the multiframe module is already installed, skip to step 11.
2 End your logic analysis session.
a Exit all logic analysis sessions. In the session manager, select 
Shutdown.
b At the query, select Powerdown.
c When the “OK to turn off power or reset system” message appears, 
turn the instrument off.
d Remove power from the instrument.
3 Disconnect the power cable and all data and peripheral cables from the 
rear panel.
4 Move the instrument to a static-safe work area.
5 Lay the instrument on its side so the handle side is up.
6 Using a Torx T10 screwdriver, remove two feet and one screw at the 
center rear of the cover that secures the bottom cover to the frame.