Specifications
153
Chapter 1: Agilent Technologies 16700A/B-Series Logic Analysis System
The System Administration Tools
• Show Activity: Not a test; provides continuous output of signal input 
levels. 
HP16610A Emulator Module 
• Internal PV Test: A loop back connector must be installed. 
NOTE: For complete information on self tests, test options, troubleshooting, and 
service procedures, refer to the optional service guides available for the 
system or the desired modules.
Saving and Reloading System Settings
The Save System Settings and Load System Settings fields are 
located under the Admin tab of the System Administration Tools 
dialog. By saving your system settings to a flexible disk or a mounted 
directory, you create a backup file that can be used to quickly setup 
new systems, or restore a current system's settings after a re-ignite 
procedure (see page 154).
To save or reload your system settings, select the desired items, then 
select Save to File, or Load Settings. If an item is not valid, or was not 
initially saved to the file, the selection is greyed out in the interface. 
Also, a .set file extension is automatically added for you.
Flexible Disk Backup - Re-ignite
NOTE: Unless changed in the file browser, the flexible disk is the default drive when 
saving a backup file. If you are going to re-ignite your logic analysis system, 
you MUST save the settings to the flexible disk or a mounted directory. Files 
saved on the analyzer's hard disk will be lost during the re-ignite procedure 
(see page 154).
What System Settings are Saved
• Printer Settings (see page 154) 
• Network Settings (see page 154)
• User Account Information (see page 156)