Specifications
74
Chapter 1: Agilent Technologies 16700A/B-Series Logic Analysis System
Overview - Multiple Frames Configuration
Triggering with the Port In/Out Signal (see page 97)
Group Run with OR Trigger (16715 and newer analyzers only)
The "Group Run with OR Trigger" connects 16715 and newer logic 
analyzer modules together so when any one analyzer in the group finds 
its trigger, all analyzers in the group trigger. An example of this kind of 
a measurement is when you want to monitor multiple busses for a 
glitch or desired data pattern. If any one analyzer triggers, then all 
other analyzers in the group will trigger. You are left with a data set for 
each bus at the time the glitch or data pattern occurred.
The following examples show the different Group Run Arming Tree 
configurations: 
• One frame; Two analyzers; Group Run OR Trigger (see page 76)
• One frame; Three analyzers; Group Run OR Trigger (see page 76)
• Two frames; Two analyzers; Group Run OR Trigger (see page 76)
• Two frames; Three analyzers; Group Run OR Trigger (see page 77)
• Three frames; Three analyzers; Group Run and Group Run OR Trigger (see 
page 78)
• Three frames; Three analyzers; Group Run OR Trigger (see page 78)
• Two frames; Two analyzers; Group Run (see page 79) 
3. Analyzer Trigger 
Configuration
In each analyzer module, under the Trigger tab, under Trigger 
Functions, select the "OR Trigger" macro then select the Replace field. 
Configure the trigger macro as required by your measurement. The 
default OR Trigger macro is shown below.