Technical data
240 Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide
11 :DEMO Commands
:DEMO:FUNCtion:PHASe:PHASe
 (see page 790)
Command Syntax
:DEMO:FUNCtion:PHASe:PHASe <angle>
<angle> ::= angle in degrees from 0 to 360 in NR3 format
For the phase shifted sine demo signals, the 
:DEMO:FUNCtion:PHASe:PHASe command specifies the phase shift in the 
second sine waveform.
Query Syntax
:DEMO:FUNCtion:PHASe:PHASe?
The :DEMO:FUNCtion:PHASe:PHASe? query returns the currently set phase 
shift.
Return Format
<angle><NL>
<angle> ::= angle in degrees from 0 to 360 in NR3 format
See Also • "Introduction to :DEMO Commands" on page 237
• ":DEMO:FUNCtion"  on page 238