Technical data
Obsolete and Discontinued Commands 33
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide 727
:MEASure:TDELta
 (see page 790)
Query Syntax
:MEASure:TDELta?
The :MEASure:TDELta? query returns the time difference between the 
Tstop marker (X2 cursor) and the Tstart marker (X1 cursor).
Tdelta = Tstop -  Tstart
Tstart is the time at the start marker (X1 cursor) and Tstop is the time at 
the stop marker (X2 cursor). No measurement is made when the 
:MEASure:TDELta? query is received by the oscilloscope. The delta time 
value that is output is the current value. This is the same value as the 
front-panel cursors delta X value.
Return Format
<value><NL>
<value> ::= time difference between start and stop markers in NR3 format
See Also • "Introduction to :MARKer Commands" on page 318
• "Introduction to :MEASure Commands" on page 340
• ":MARKer:X1Position"  on page 320
• ":MARKer:X2Position"  on page 322
• ":MARKer:XDELta"  on page 324
• ":MEASure:TSTArt"  on page 729
• ":MEASure:TSTOp"  on page 730
NOTE
The :MEASure:TDELta command is an obsolete command provided for compatibility to 